Search

IKA Magnetic Stirrers RCT basic ready-to-go Solution

RCT basic ready-to-go Solution
SKU: IKA0010011525
Estimated Delivery Date: 14 Working Days
$1,368.00
decrease increase

RCT basic ready-to-go Solution

The RCT basic ready-to-go Solution includes all components required for precise temperature control of your sample with the RCT basic magnetic stirrer.

Stand for safe positioning
This complete solution includes a stand rod together with an extension arm and a boss head clamp. They ensure the correct and safe positioning of the PT 1000 temperature sensor, which is also included in the delivery, because it should always be located outside the drum created during stirring and should be immersed in the medium to a depth of at least 20 mm. Thanks to the stand, the position of the temperature sensor is precisely adapted to the reaction vessel and the level in vertical and horizontal alignment.

Multifunctional silicone cover
In addition, the bundle includes a universal silicone cover for beakers with 600 and 1000 ml. It has integrated feedthroughs for the temperature sensor. The chemically highly resistant cover fulfills three functions at once: It is a splash guard, minimizes energy requirements when used as a lid, and reduces the noise that can occur when air is drawn in during rapid stirring.

Scope of delivery

  • H 16 V Support rod
  • BC 1000 Beaker cap
  • Magnetrührstab Set 30+40
  • Screw driver
  • RCT basic
  • PT 1000.60 Temperature sensor, stainless steel
  • H 38 Holding rod
  • H 44 Boss head clamp

RCT basic ready-to-go Solution

The RCT basic ready-to-go Solution includes all components required for precise temperature control of your sample with the RCT basic magnetic stirrer.

Stand for safe positioning
This complete solution includes a stand rod together with an extension arm and a boss head clamp. They ensure the correct and safe positioning of the PT 1000 temperature sensor, which is also included in the delivery, because it should always be located outside the drum created during stirring and should be immersed in the medium to a depth of at least 20 mm. Thanks to the stand, the position of the temperature sensor is precisely adapted to the reaction vessel and the level in vertical and horizontal alignment.

Multifunctional silicone cover
In addition, the bundle includes a universal silicone cover for beakers with 600 and 1000 ml. It has integrated feedthroughs for the temperature sensor. The chemically highly resistant cover fulfills three functions at once: It is a splash guard, minimizes energy requirements when used as a lid, and reduces the noise that can occur when air is drawn in during rapid stirring.

Scope of delivery

  • H 16 V Support rod
  • BC 1000 Beaker cap
  • Magnetrührstab Set 30+40
  • Screw driver
  • RCT basic
  • PT 1000.60 Temperature sensor, stainless steel
  • H 38 Holding rod
  • H 44 Boss head clamp

Filters
Sort
display